- Rack inventory management
- Dashboards
- Account settings
- Administration functions, such as
- License management
- Desktop client download
- User management
- Authentication server configuration
- Customer management (colo feature, available with the Data Center Operation for Colo license)
Supported browsers and OS
Data Center Operation web client minimum browser and OS requirements:
- Internet Explorer 10
- Chrome 52
- Firefox 49
- Safari 9.1.3
- iOS 9.3.5
- Android 5.1
- Microsoft Edge 20.10240.16384.0
Access and language settings
To access the web client, use a browser to launch to the IP address or hostname of the DCO server <serverIPaddress>
and log in.
If you're not an English speaker, you can select your preferred language in Profile>Language (your profile image in the upper right corner).
Security
When connecting to the DCO server from a web browser, you may receive warnings about the security certificate needed for secure communication. The DCO server is installed with a self-signed security certificate. It is recommended, after the installation of DCO is complete, to replace this with a security certificate issued by a trusted certificate authority. For information about certificates and how to replace the default self-signed certificate with one you purchase from a trusted certificate authority, see Working with SSL certificates and Changing SSL certificate on the server.
If you try logging in with wrong credentials 5 times, your account will be locked for 10 minutes.
Rack inventory and dashboards
The web client rack inventory allows you to see any part of the DCO data center infrastructure model you have been granted access to and drill down through locations and rooms to the rack inventory. You may have been granted with rights to view or edit all or parts of the rack inventory. For example, depending on your user rights, you can:
- View a graphical representation of locations, rooms including walls, doors, windows, cages, and floor-mounted equipment
- View equipment in racks and their properties, such as servers, blade chassis, network equipment, and rack PDUs
- Edit equipment in racks and their properties, such as servers, blade chassis, network equipment, and rack PDUs
- Connect equipment in racks to rack PDUs for power or disconnect
- View power and space usage for the selected room, cage, or equipment
- View power history for the selected room, cage, or rack
- View capacity overview for the entire solution or a selected location
- View audit trail for the selected room, cage, or equipment, listing changes made to the infrastructure, such as connecting servers to rack PDUs or changing equipment names
There's an upper limit to everything
The web client does not include all functionality included in the graphical editor in the DCO desktop client. For example, you cannot:
- Add, change, or delete locations, rooms, or floor-mounted equipment (including racks)
- Design or edit room layouts
- Configure network connections
- Use custom tags
- Add, change, or delete work orders
3 comments
Why you don't enable network connectivity feature in web client? Really necessary functionality.
Hi Aliaksei Marchuk,
More and more functionality is being added to the ITA web client. Network connectivity is under consideration.
You can view network paths in the ITA web client now, but you can't edit them at this time.
Best,
Jackie
Hi Jackie,
I understand that web client continuously improving. From my point of view, this is quite ridiculous when you allow add server to a rack, create power connections, but not allow to create network connections. It looks like I can create server, mount it in a rack, connect it to PDU, but have to open client to (only) connect server to network device.
Hope, this functionality will be added in the nearest software update.